Version 6.6 777 Mediant 800 MSBR
User's Manual 66. Configuration Parameters Reference
Therefore, in addition to filtering Syslog messages according to IP
address, the messages can be filtered according to Facility level.
[16] = (Default) local use 0 (local0)
[17] = local use 1 (local1)
[18] = local use 2 (local2)
[19] = local use 3 (local3)
[20] = local use 4 (local4)
[21] = local use 5 (local5)
[22] = local use 6 (local6)
[23] = local use 7 (local7)
Web: Activity Types to
Report via Activity Log
Messages
[ActivityListToLog]
Defines the Activity Log mechanism of the device, which sends log
messages to a Syslog server for reporting certain types of Web
operations according to the below user-defined filters.
[pvc] Parameters Value Change = Changes made on-the-fly to
parameters. Note that the ini file parameter,
EnableParametersMonitoring can also be used to set this option,
using values [0] (disable) or [1] (enable).
[afl] Auxiliary Files Loading = Loading of auxiliary files.
[dr] Device Reset = Reset of device via the 'Maintenance Actions
page.
Note: For this option to take effect, a device reset is required.
[fb] Flash Memory Burning = Burning of files or parameters to flash
(in 'Maintenance Actions page).
[swu] Device Software Update = cmp file loading via the Software
Upgrade Wizard.
[ard]
Access to Restricted Domains = Access to restricted domains,
which include the following Web pages:
(1) ini parameters (AdminPage)
(2) General Security Settings
(5) Software Upgrade Key Status
(7) Web & Telnet Access List
(8) WEB User Accounts
[naa] Non-Authorized Access = Attempt to access the Web
interface with a false or empty user name or password.
[spc] Sensitive Parameters Value Change = Changes made to
sensitive parameters:
(3) Default Gateway IP Address
(4) ActivityListToLog
[ll] Login and Logout = Every login and logout attempt.
For example: ActivityListToLog = 'pvc', 'afl', 'dr', 'fb', 'swu', 'ard', 'naa',
'spc'
Note: For the ini file, values must be enclosed in single quotation
marks.
CLI: oamp-default-
network-src data/voip
[OAMPDefaultNetworkS
ource]
Defines the network interface from where the device sends Syslog
messages to a Syslog server.
[0] Data (default) = Syslog messages are sent from the WAN
interface.
[1] VoIP= Syslog messages are sent from the VoIP LAN interface