Version 6.6 895 Mediant 800 MSBR
User's Manual 66. Configuration Parameters Reference
Parameter Description
(similar to ETSI).
[20] T1 HKT ISDN = ISDN PRI (T1) protocol for the Hong
Kong - HKT.
[21] E1 QSIG = ECMA 143 QSIG over E1
[22] E1 TNZ = ISDN PRI protocol for Telecom New Zealand
(similar to ETSI)
[23] T1 QSIG = ECMA 143 QSIG over T1
[30] E1 FRENCH VN6 ISDN = France Telecom VN6
[31] E1 FRENCH VN3 ISDN = France Telecom VN3
[34] T1 EURO ISDN =ISDN PRI protocol for Euro over T1
[35] T1 DMS100 Meridian ISDN = ISDN PRI protocol for the
Nortel™ DMS Meridian switch
[36] T1 NI1 ISDN = National ISDN 1 PRI protocol
[40] E1 NI2 ISDN = National ISDN 2 PRI protocol over E1
[50] BRI EURO ISDN = Euro ISDN over BRI
[51] BRI N12 ISDN
[52] BRI DMS 100 ISDN
[53] BRI 5ESS 10 ISDN
[54] BRI QSIG = QSIG over BRI
[55] BRI VN6 = VN6 over BRI
[56] BRI NTT = BRI ISDN Japan (Nippon Telegraph)
[57] BRI IUA
Notes:
All PRI trunks must be configured as the same line type (either
E1 or T1). The device can support different variants of CAS
and PRI protocols on different E1/T1 spans (no more than four
simultaneous PRI variants).
BRI trunks can operate together with E1 or T1 trunks.
[ProtocolType_x]
Defines the protocol type per trunk ID (where x denotes the Trunk
ID and 0 is the first trunk). For more information, see the
ProtocolType parameter.
[ISDNTimerT310]
Defines the T310 override timer for DMS, Euro ISDN, and ISDN
NI2 variants. An ISDN timer is started when a Q.931 Call
Proceeding message is received. The timer is stopped when a
Q.931 Alerting, Connect, or Disconnect message is received from
the other end. If no ISDN Alerting, Progress, or Connect message
is received within the duration of T310 timer, the call clears.
The valid value range is 0 to 600 seconds. The default is 0 (i.e.,
use the default timer value according to the protocol's
specifications).
Notes:
For this parameter to take effect, a device reset is required.
When both the parameters ISDNDmsTimerT310 and
ISDNTimerT310 are configured, the value of the parameter
ISDNTimerT310 prevails.
[ISDNDMSTimerT310]
Defines the override T310 timer for the DMS-100 ISDN variant.
T310 defines the timeout between the receipt of a Proceeding
message and the receipt of an Alerting/Connect message.
The valid range is 10 to 30. The default is 10 (seconds).