Version 6.6 987 Mediant 800 MSBR
User's Manual 66. Configuration Parameters Reference
Parameter Description
adaptation
[AGCDisableFastAdapta
tion]
Note: For this parameter to take effect, a device reset is required.
Energy Detector Parameters
Enable Energy Detector
CLI: energy-detector-
enable
[EnableEnergyDetector]
Enables the Energy Detector feature. This feature generates events
(notifications) when the signal received from the PSTN is higher or
lower than a user-defined threshold (defined by the
EnergyDetectorThreshold parameter).
[0] Disable (default)
[1] Enable
Energy Detector Quality
Factor
CLI: energy-detector-
sensitivity
[EnergyDetectorQuality
Factor]
Defines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest sensitivity and 10 the
highest sensitivity. The default is 4.
Energy Detector
Threshold
CLI: energy-detector-
threshold
[EnergyDetectorThresh
old]
Defines the Energy Detector's threshold. A signal below or above this
threshold invokes an 'Above' or 'Below' event.
The threshold is calculated as follows:
Actual Threshold = -44 dBm + (EnergyDetectorThreshold * 6)
The valid value range is 0 to 7. The default is 3 (i.e., -26 dBm).
Pattern Detection Parameters
Note: For an overview on the pattern detector feature for TDM tunneling, see DSP Pattern
Detector on page 288.
Web: Enable Pattern
Detector
[EnablePatternDetector]
Enables the Pattern Detector (PD) feature.
[0] Disable (default)
[1] Enable
[PDPattern]
Defines the patterns that can be detected by the Pattern Detector.
The valid range is 0 to 0xFF.
Note: For this parameter to take effect, a device reset is required.
[PDThreshold]
Defines the number of consecutive patterns to trigger the pattern
detection event.
The valid range is 0 to 31. The default is 5.
Note: For this parameter to take effect, a device reset is required.

Table of Contents