F00-300-17
UP-ADJ
Adjusts the image write start position in main scanning direction when
pick-up is from the upper cassette. Be sure to select the upper cassette on
the User screen in advance.
Settings range
0 ~ 255 (standard: 128)
A higher value leads to a movement to the rear.
(unit: about 0.06mm)
F00-300-18
LOW-ADJ
Adjusts the image write start position in main scanning direction when
pick-up is from the lower cassette. Be sure to select the upper cassette on
the User screen in advance.
Settings range
0 ~ 255 (standard: 128)
A higher value leads to a movement to the rear.
(unit: about 0.06mm)
F00-300-19