CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-61
<HV-TR (transfer high-voltage output adjustment by condition)>
F00-300-25
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
TRY-OFS-Y/M/C/K
Adjusts the transfer high-voltage output.
Settings range
-5 ~ +5 (standard: 0)
Unit: 1.0 µA
If you have changed the settings of ‘TRY-OFS-C/M/Y/K’,
check to make sure that the value of ‘TR-#’ for each zone is
‘0’; otherwise, enter ‘0’.
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
Note 1: The setting of this item will return to the default value when the PCB is re-
placed or the RAM is cleared, requiring input once again. Be sure to record
any new setting you have made on the service label.
<M> <S> <R> <P> <F>
ADJUST
DISP
FUNC
COUNTER
OPTION
TEST
HV-TR-Y 1/4 READY READY
TR-OFS-Y
xxxx
BODY
BODY
BODY
xxx
xxx
xxx
˚C
%
g
ZONE A
ZONE B
ZONE C
0.0g
580g
1800g
580g
1800g
-----g
see
see
see
2/4
3/4
4/4
to
to
to