COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-65
<HV-SP (separation high-voltage output fine-adjustment by
condition)>
F00-300-27
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
SP-OFST
Adjusts the transfer high-voltage output.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
Note 1: The setting of this item will return to the default value when the PCB is re-
placed or the RAM is cleared, requiring input once again. Be sure to record
any new setting you have made on the service label.
<M> <S> <R> <P> <F>
ADJUST
DISP
FUNC
COUNTER
OPTION
TEST
HV-SP 1/4 READY READY
SP-OFST
xxxx
BODY
BODY
BODY
ZONE A
ZONE B
ZONE C
0.0g
580g
1800g
580g
1800g
-----g
see
see
see
2/4
3/4
4/4
to
to
to
xxx
xxx
xxx
xxx
xxx
xxx
˚C
%
g