SERVICE MODE
S-69
<HV-FS (fine-adjustment for pre-fixing high-voltage output ac-
cording to conditions)>
F00-300-29
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks Same as the reading under ‘DISPLAY > ANALOG’
FS-OFST *
1
Adjusts the transfer high-voltage output.
Settings range
–5 ~ +5 (Standard: 0)
Unit: 25 µA
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
STMT-MD *
1
Adjust the high-voltage output for size of STMT
Settings range
–1 ~ +9 (Standard: 0)
<M> <S> <R> <P> <F>
ADJUST
DISP
FUNC
COUNTER
OPTION