CAPTUS
®
600
THYROID UPTAKE SYSTEM
OWNER’S MANUAL
Capintec, Inc.
Sales and Marketing
and Customer Support
6 Arrow Road
Ramsey, NJ 07446
Phone (800) ASK-4CRC
Fax (201) 825-1336
Capintec, Inc.
Service Center
620 Alpha Drive
Pittsburgh, PA 15238
Phone (800) 227-6832
Fax (412) 963-0610
Copyright
©
1995 Capintec, Inc.
CAPTUS
®
is a registered trademark of Capintec, Inc.
ALL RIGHTS RESERVED
Manual Stock No. 9250-0072
Rev. M – November 2007
2
Table of Contents
Default Chapter
3
Table of Contents
3
Preface
9
Capintec, Inc
9
Safety
11
Symbol Definitions
11
Warning and Caution Labels
12
Cautions and Notes
15
General Safety Tips
16
Functional & Technical Description
17
General
17
Technical Description
17
Detector
18
Multichannel Analyzer
18
Technical Specifications
18
Thyroid Uptake Stand
18
System Power Requirements
19
Environment Requirements
19
Operational
19
Storage
19
Isolation Transformer
20
Printer
20
Readout Unit
20
Nuclear Data
20
Calibration Source Data
21
Multichannel Pulse Height Analyzer
21
Diagnostics and Test
21
Utilities
21
Display
21
Two Separate Inputs
21
Probe Detector
22
Well Detector - Optional
22
Regulatory Listings
22
Emc
22
Electrical
22
ETL Listed
22
Functional Description
23
Thyroid Uptake
23
Thyroid Uptake Nuclides
23
Pre-Dose Measurement
23
Thyroid Uptake Protocols
23
One Capsule Method
24
Standard Capsule Method
24
Two Capsule Method
24
Multi-Capsules
25
Wipe Tests
25
Lab Tests - Urine
25
Lab Tests - Blood
26
Staff Bioassay
26
General Operating Overview
27
Turn on System
27
Log-On Password
27
System Functions
28
Probe Screen
29
Well Screen
29
HOME Key
30
Changing from PROBE to WELL Functions
30
Changing from WELL to PROBE Functions
30
Contrast
30
Screen Dimmer
30
FUNCTION Keys
31
PRINT Key
31
UTIL Key
31
Keyboard
32
BSP Key
32
Prompt
32
ARROW Keys
32
Alphanumeric Entries
33
Entries with Number and Letters
33
SPACE Key
33
Decimal Point
33
Blank Entries
34
Invalid Values
34
ENTERING DATE and TIME
34
Setup Password
34
YES or no Answers
35
Counting Methods
35
Measurement Errors
36
High Voltage Adjustment
36
Offset Voltage Adjustment
36
Display Contrast Adjustment
37
Data Entry Input Limits
37
Thyroid Uptake Protocols
37
Thyroid Uptake Measurements
37
Cs137 Standard
37
Bioassay Protocol
38
Additional Nuclide
38
Blood Volume
38
RBC Survival Measurement
38
Patient Demographics
38
Wipe
38
Description
38
Background Counting
38
Generic Conversion Factors
38
Trigger Levels
39
Staff Data
39
System Setup
41
Installation
41
Environment Requirements
41
Operational
41
Storage
41
Power Requirements
42
Turn on Procedure
42
General Operational Setup
43
Acceptance Testing
43
Setting up for Thyroid Uptakes or Wipe Tests
44
Setting up for Lab Tests (Urine & Blood)
44
Setup for Staff Bioassay
44
Setup for Multichannel Analyzer
44
System Initialization
45
Date & Time Setup
45
2. D a te E N Tr y F O R M a T
45
Changing the Time and Date Setting
46
Setting Hospital or Facility Name
47
Curies / Becquerel Setup
48
Cs137 STANDARD SETUP
51
Chi-Square Test Setup
53
Conversion Factors
55
Entering Nuclide Name
57
Selecting Measure or Input CF
58
Input CF
58
Measure CF
59
Acceptance & Quality Assurance Tests
63
Acceptance Tests
63
Quality Assurance Tests
63
Daily Tests
63
Monthly Tests
63
Quarterly Tests
64
Calibration Test
64
Chi-Square Test
67
Auto Calibration Test
67
Mda Test
71
4. Diag N O Stics
74
Diagnostics Printout
75
System Configuration
75
Nuclide Data
75
Additional Nuclides
76
User Keys
76
Standard Source
76
PROM Values
76
Memory Tests
76
Thyroid Uptake Setup
79
Counting Methods
79
Protocols
82
Adding a Protocol
84
Editing a Protocol
89
Deleting a Protocol
89
Printing Protocol Information
89
Thyroid Uptake General Instructions
91
Accessing Thyroid Uptake Studies
91
Entering Patient Demographics
92
Selecting Protocol
93
Selecting Patient
94
Printing Thyroid Uptake Patient Summary
95
Viewing Patient Information
95
Selecting Patient to Measure
96
Measuring the Neck and Thigh
97
Pre-Dose Measurement
99
Printing Results
101
Thyroid Uptake: One Capsule Method
103
General Procedure
103
Pre-Dose Measurement
103
Entering Capsule Data
104
Measuring the Capsule(S)
105
Administering the Dose Later
108
Administered Dose
108
Entering Administered Dose Data
109
Uptake Measurement
110
Viewing Results
111
Thyroid Uptake: Two Capsule Method
113
General Procedure
113
Pre-Dose Measurement
113
Entering Administered Dose
113
Measuring the Reference Capsule(S)
115
Uptake Measurement
118
Viewing Results
119
Thyroid Uptake: Standard Capsule Method
121
General Procedure
121
Accessing Tu Standard
121
Adding a Tu Standard
122
Editing a Tu Standard
123
Deleting a Tu Standard
123
Printing Tu Standard Data
124
Measuring Tu Standard
124
Selecting Standard for Tu Study
126
Pre-Dose Measurement
127
Entering Administered Dose
127
Uptake Measurement
129
Viewing Results
129
Wipe Test Setup
133
Introduction
133
Wipe Descriptions
134
Entering Data for a Wipe Location
134
Adding a Location
135
Editing or Deleting a Location
136
Trigger Level/Count Time
136
Generic Conversion Factors
138
Additional Nuclides
139
User Key Assignment
141
Wipe Test
143
Introduction
143
Measuring Background
143
Measuring a Wipe
145
Wipe Results
147
Wipe Graphics Screen
148
Scale/Cursor Mode
149
Activity of a Nuclide
149
Activity for Generic Conversion Factor
149
Wipe Report
149
Interpreting Wipe Results
151
Lab Tests Setup
153
Introduction
153
General Procedure
153
Starting Lab Tests
154
Entering Patient Demographics
155
Measurement Procedure
156
Lab Tests: Urine Test
159
Introduction
159
Performing Schilling Test Measurements
159
Lab Tests: Blood Tests
163
Introduction
163
BLOOD VOLUME (Cr51)
163
Blood Volume (I125)
168
Red Blood Cell Survival
172
Staff Bioassay
177
Staff Bioassay Data
177
Adding Staff Member
178
Editing Staff Member Data
179
Deleting a Staff Member
180
Entering the Bioassay Protocol
180
X-Ray/Gamma Ratio
181
Making Bioassay Measurements
181
Printing Staff Bioassay Results
183
Multichannel Analyzer Setup
187
Introduction
187
Mca Setups
187
Adding a Setup
189
Editing a Setup
192
Deleting a Setup
192
Printing All the Setups
192
Multichannel Analyzer Operation
193
Mca Measurements
193
Calibration
194
Measuring Background
194
Measuring a Source
196
Activity of a Nuclide
200
Exiting MCA Measurement
200
Cleaning and Maintenance
201
Introduction
201
Cleaning Instructions
201
Preventative Maintenance
202
Collimator Block Inspection
203
Servicing
203
Disposal
204
Fuse Servicing
205
Power Line Fuses
205
Readout Unit Fuses
206
Printer Fuse
206
Accessories and Replacement Parts
207
Shipping
207
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Capintec CAPTUS 600 and is the answer not in the manual?
Ask a question
Capintec CAPTUS 600 Specifications
General
Type
Thyroid Uptake System
Power Requirements
100-240 VAC, 50/60 Hz
Calibration Sources
Cs-137, Co-57
Display
LCD
Uptake Measurement Range
0.1 μCi
Related product manuals
Capintec CAPTUS 3000
338 pages