EasyManuals Logo

Cisco Catalyst 3750-X Command Reference

Cisco Catalyst 3750-X
1244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1023 background imageLoading...
Page #1023 background image
2-991
Catalyst 3750-X and 3560-X Switch Command Reference
OL-29704-01
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
vmps server
vmps server
Use the vmps server global configuration command on the switch stack or on a standalone switch to
configure the primary VLAN Membership Policy Server (VMPS) and up to three secondary servers. Use
the no form of this command to remove a VMPS server.
vmps server ipaddress [primary]
no vmps server [ipaddress]
Syntax Description
Defaults No primary or secondary VMPS servers are defined.
Command Modes Global configuration
Command History
Usage Guidelines The first server entered is automatically selected as the primary server whether or not primary is
entered. The first server address can be overridden by using primary in a subsequent command.
If a member switch in a cluster configuration does not have an IP address, the cluster does not use the
VMPS server configured for that member switch. Instead, the cluster uses the VMPS server on the
command switch, and the command switch proxies the VMPS requests. The VMPS server treats the
cluster as a single switch and uses the IP address of the command switch to respond to requests.
When using the no form without specifying the ipaddress, all configured servers are deleted. If you
delete all servers when dynamic-access ports are present, the switch cannot forward packets from new
sources on these ports because it cannot query the VMPS.
Examples This example shows how to configure the server with IP address 191.10.49.20 as the primary VMPS
server. The servers with IP addresses 191.10.49.21 and 191.10.49.22 are configured as secondary
servers:
Switch(config)# vmps server 191.10.49.20 primary
Switch(config)# vmps server 191.10.49.21
Switch(config)# vmps server 191.10.49.22
ipaddress IP address or hostname of the primary or secondary VMPS servers. If you specify a
hostname, the Domain Name System (DNS) server must be configured.
primary (Optional) Decides whether primary or secondary VMPS servers are being
configured.
Release Modification
12.2(53)SE2 This command was introduced.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing

Related product manuals