2-720
Catalyst 3750-X and 3560-X Switch Command Reference
OL-29704-01
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
show logging onboard
Current slot : 1
Current uptime : 0 years 0 weeks 0 days 0 hours 55 minutes
--------------------------------------------------------------------------------
Reset | |
Reason | Count |
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
This is an example of output from the show logging onboard voltage summary command:
Switch# show logging onboard voltage summary
--------------------------------------------------------------------------------
VOLTAGE SUMMARY INFORMATION
--------------------------------------------------------------------------------
Number of sensors : 8
Sampling frequency : 60 seconds
Maximum time of storage : 3600 minutes
--------------------------------------------------------------------------------
Sensor | ID | Maximum Voltage
--------------------------------------------------------------------------------
12.00V 0 12.567
5.00V 1 5.198
3.30V 2 3.439
2.50V 3 2.594
1.50V 4 1.556
1.20V 5 1.239
1.00V 6 0.980
0.75V 7 0.768
--------------------------------------------------------------------------------
Nominal Range Sensor ID
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
Related Commands Command Description
clear logging onboard Removes the OBFL data in the flash memory.
hw-module module [switch-number] logging
onboard
Enables OBFL.