User's Manual
106
Figure 6-61 Area
●
Click or white dot on detect region frame, and drag to adjust its range.
●
Click or to set the minimum size or maximum size of the face detection area.
System triggers an alarm once the size of detected target is between the maximum size
and the minimum size.
Step 6 Click
Deployment Time to select a schedule from the drop-down list.
System triggers corresponding alarm actions only during the alarm deployment period.
You can select an existing schedule from the Deployment Time drop-down list. You can
also add a new schedule. For details, see "8.8.4 Schedule".
Step 7 Click
Action to set alarm action. See "8.4.1 Alarm Actions" for detailed information.
Step 8 Click Save.
6.3.5.3 Configuring Device Face Database
You can create face databases on the device to manage face images for face recognition (by device).
For details, see "6.3.3.4 Configuring Device Face Database".
6.3.5.4 Configuring Face Recognition (by Device)
Configure face recognition rules. For details, see "6.3.3.5 Configuring Face Recognition (by Device)".
6.3.5.5 Live View
Smart panel display. You can view real-time face detection and human face recognition images. For
details, see "6.3.2.5 Live View of Face Recognition".