031914 7-17
WEIGHING
INDIVIDUAL TARGET WEIGHTS: If “yes,” no
Target Weight adds below 19 parameters.
% CORRECTIONS: The “% Correction” parameter
sets the percentage of “Weight Control Corrections”
for the drafts or stacks that do not fall in the “Weight
Tolerance” range. Illustration 42) The adjustment
range is 0 to 100 percent. The “% Correction” can
also be adjusted on the “Weight Data” and the
“Adjustments” screens. Fine-tune Correction
Percentage on the Adjustments screen and enter
that setting in this parameter for the next time you
run this product.
WEIGHT METHOD: The “Weight Method”
parameter allows you to select “U.S. Standard”
Weight Control or “EEC” Weight Control for use in
Europe. (Illustration 43)
ILLUSTRATION 42
% CORRECTIONS
ILLUSTRATION 43
WEIGHT METHOD