Installing the ETERNUS CS800 S5 Modules Installing the Components in the Rack
U41840-J-Z125-7-76 91
5. Secure the left slide rail to the front pillar using the pre-mounted M5 centering screw (2
in Figure 48) and the M5 pan head screw (3).
6. For the right slide rail, insert the pins in the holes of the rear pillar, and secure the other
side of the slide rail to the front pillar in the same way as the left slide rail.
Installing the JX40 Module
1. Install the JX40 Storage Module in the rack.
V
CAUTION!
When installing the storage module to the rack, make sure to have the right and
left sides and the bottom of the module by two or more people.
Failure to do so may cause injury.
2. Fix the module in the rack.
Secure the JX40 subsystem within the rack using the knurled thumb screws on each
side. The left thumb srew is part of the separate bezel, the right one is part of the
enclosure.
Figure 49: Fasten the JX40 Storage Module in the Rack
Installing the DX80 S2 Module
1. Install the DX80 S2 storage module in the rack
V
CAUTION!
When installing the storage module to the rack, make sure to have the right and
left sides and the bottom of the module by two or more people.
Failure to do so may cause injury.