101
Use undo lsa-generation-interval to restore the default.
By default, the maximum interval is 5 seconds, the minimum interval is 0 milliseconds, and the
incremental interval is 5000 milliseconds..
With this command configured, when network changes are not frequent, LSAs are generated at the
initial-interval. If network changes become frequent, LSA generation interval is incremented by a
specified value each time a generation happens, up to the maximum-interval.
Related commands: lsa-arrival-interval.
Examples
# Configure the maximum LSA generation interval as 2 seconds, minimum interval as 100 milliseconds
and incremental interval as 100 milliseconds.
<Sysname> system-view
[Sysname] ospf 100
[Sysname-ospf-100] lsa-generation-interval 2 100 100
lsdb-overflow-limit
Syntax
lsdb-overflow-limit number
undo lsdb-overflow-limit
View
OSPF view
Default level
2: System level
Parameters
number: Specifies the upper limit of external LSAs in the LSDB, in the range of 1 to 1000000.
Description
Use lsdb-overflow-limit to specify the upper limit of external LSAs in the LSDB.
Use undo lsdb-overflow-limit to restore the default.
External LSAs in the LSDB are not limited by default.
Examples
# Specify the upper limit of external LSAs as 400000.
<Sysname> system-view
[Sysname] ospf 100
[Sysname-ospf-100] lsdb-overflow-limit 400000
maximum load-balancing (OSPF view)
Syntax
maximum load-balancing maximum
undo maximum load-balancing