EasyManua.ls Logo

HP 6125G - Ripng Default-Route

HP 6125G
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
220
View
System view
Default level
2: System level
Parameters
process-id: RIPng process ID, in the range of 1 to 65535. The default value is 1.
Description
Use ripng to create a RIPng process and enter RIPng view.
Use undo ripng to disable a RIPng process.
By default, no RIPng process is enabled.
Before configuring global RIPng parameters, you must create a RIPng process. This requirement
does not apply to interface RIPng parameter configuration.
After you disable a RIPng process, the RIPng parameters on interface running the process also
become ineffective.
Examples
# Create RIPng process 100 and enter its view.
<Sysname> system-view
[Sysname] ripng 100
[Sysname-ripng-100]
# Disable RIPng process 100.
[Sysname] undo ripng 100
ripng default-route
Syntax
ripng default-route { only | originate } [ cost cost ]
undo ripng default-route
View
Interface view
Default level
2: System level
Parameters
only: Indicates that only the IPv6 default route (::/0) is advertised through the interface.
originate: Indicates that the IPv6 default route (::/0) is advertised without suppressing other routes.
cost: Metric of the advertised default route, in the range of 1 to 15, with a default value of 1.
Description
Use ripng default-route to advertise a default route with the specified routing metric to a RIPng neighbor.
Use undo ripng default-route to stop advertising or forwarding the default route.
By default, a RIP process does not advertise any default route.