114
ospf timer retransmit
Syntax
ospf timer retransmit interval
undo ospf timer retransmit
View
Interface view
Default level
2: System level
Parameters
interval: LSA retransmission interval in seconds, in the range of 1 to 3600.
Description
Use ospf timer retransmit to set the LSA retransmission interval on an interface.
Use undo ospf timer retransmit to restore the default.
The interval defaults to 5s.
After sending an LSA, an interface waits for an acknowledgement packet. If the interface receives no
acknowledgement within the retransmission interval, it will retransmit the LSA.
The retransmission interval should not be so small to avoid unnecessary retransmissions.
Examples
# Set the LSA retransmission interval to 8 seconds.
<Sysname> system-view
[Sysname] interface vlan-interface 10
[Sysname-Vlan-interface10] ospf timer retransmit 8
ospf trans-delay
Syntax
ospf trans-delay seconds
undo ospf trans-delay
View
Interface view
Default level
2: System level
Parameters
seconds: LSA transmission delay in seconds, in the range of 1 to 3600.
Description
Use ospf trans-delay to set the LSA transmission delay on an interface.
Use undo ospf trans-delay to restore the default.
The LSA transmission delay defaults to 1 second.