548
Configuring trunking mode calling
Network requirements
As shown in Figure 576, Router A and Router B are connected through an FXO trunk line. It is required
that Telephone 1111 can call telephone 2222.
Figure 576 Network diagram
Configuring Router A
# Create a local number.
1. Select Voice Management > Local Number from the navigation tree, and then click Add to access
the page for creating a local number.
Figure 577 Creating local number 1111
2. Enter 1 for Number ID.
3. Enter 1111 for Number.
4. Select subscriber-line 8/0 from the Bound Line list.
5. Enter Telephone A for Description.
6. Click Apply.
# Create a call route.