4. Select Alone for Server Operation Mode.
5. Click Apply.
# Configure a call-out route
6. Select Voice Management > SIP Local Survival > Call-Out Route from the navigation tree, and click
Add to access the following page.
Figure 777 Configuring a call-out route
7. Enter 0 for ID.
8. Enter 55665000 for Destination Number Prefix, and 8 for Number Length.
9. Enter 2.1.1.1 for Destination IP Address.
10. Enter 8899 for Area Prefix.
11. Click Apply.
# Configure user 1000.
12. Select Voice Management > SIP Local Survival > User Management from the navigation tree, and
click Add to access the following page.
Figure 778 Configuring user 1000
13. Enter 1000 for User ID.
14. Enter 1000 for Telephone Number.
15. Enter 1000 for Authentication Username.
16. Enter 1000 for Authentication Password.
17. Click Apply.

Table of Contents

Other manuals for HP MSR SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR SERIES and is the answer not in the manual?

HP MSR SERIES Specifications

General IconGeneral
Product SeriesMSR Series
ManufacturerHP
CategoryNetwork Router
PortsVaries by model
WAN InterfacesVaries by model
LAN InterfacesVaries by model
VPN SupportYes
FirewallYes
DimensionsVaries by model
WeightVaries by model
Wireless SupportVaries by model
ManagementWeb-based, CLI
Power SupplyVaries by model
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity5% to 95% non-condensing

Related product manuals