102
Figure 84 Add an alarm entry
Table 36 Alarm entry configuration items
Item Descri
p
tion
Alarm
variable
Statics Item
Set the traffic statistics that will be collected and monitored. For more information,
see Table 37.
Interface Name
Set the name of the interface whose traffic statistics will be collected and
monitored.
Sample
Item
Interval Set the sampling interval.
Sample Type
Set the sampling type, including:
Absolute—Absolute sampling, namely, to obtain the value of the variable
when the sampling time is reached.
Delta—Delta sampling, namely, to obtain the variation value of the variable
during the sampling interval when the sampling time is reached.
Owner Set the owner of the alarm entry.

Table of Contents