84 Issue 3.3.2 / April, 2011
Program 05-12-IP : System Timing Parameters – 12
05-12-IP SYS PAR
0 0 0 2 7 0 0 0
IP = 01-08
System Default.
Item Display Programming Data Timing
Pointer Data Description Table Default
---------- ---------- -------------------------------------------------- ---------- ------------
01 0-1 Call Transfer Method – Key Telephone 0=Key Phone
02 0- Reserved 0=
03 0-1 Exclusive hold capability 0=Yes
04 0-9 Door Unlock Relay Activation Time 2=3 Sec.
05 0-7 Voice Mail Call Forward Protocol Type / mute digits 7=Enhanced
06 0-1 Linear/Circular Trunk group access 0=Linear
07 0-9 LED indication of Check in / Check out on DSS console 0=Disable
08 0- Reserved 0=
Description:
01. Call Transfer Method – Key Telephone:
This parameter allows users to use the same call transfer method as single line telephones on digital
key telephones for internal Call transfer.
It also adds the ability to transfer a trunk call to another trunk (External Call Transfer) using the Transfer
key rather than the Unsupervised Conference facility.
0 = Use Key phone’s call transfer method. 1 = Use single line telephone’s call transfer method.
2 = Use Key phone’s call transfer method and TRF for Trunk To Trunk.
3 = Use single line telephone’s call transfer method and TRF for Trunk To Trunk.
Note: When parameter is set to 2 or 3 the G1E-VSC must be Installed in the G1E system. Not necessary
in G1E+
02. Reserved
03. Exclusive Hold Capability:
If this parameter is enabled all stations can use the Exclusive Hold Function. If the parameter is disabled
no stations will be able to place calls on Exclusive hold.
0 = Enabled 1 = Disabled
04. Door Unlock Relay Activation Time:
This parameter sets the time that the door unlock relay will remain activated after the Door Unlock
function is activated by the user. The Door unlock relay is programmed in Mode 06.
0 = 1 Sec. 1 = 2 Sec. 2 = 3 Sec. ........ 9 = 10 Sec.