120 Issue 3.3.2 / April, 2011
Program 14-01-IP : SMDR Specifications
14-01-IP S.M.D.R.
0 0 0 0 0 21 0 0
IP = 01-08
System Default
Item Display Programming Data
Pointer Data Description
-------- ---------- ------------------------------------------- -----------------------
01 0-9 Call Duration Start Time 0=00 Sec.
02 0/1 Record Incoming Call 0=Record
03 0/1 Record Local Call 0=Record
04 0/1 Record Incoming Call No Answer 0=Record
05 0/1 Print out the Title 0=Yes
06 00-99 Number of records between titles 21=21
07 0- Reserved 0=
08 0-3 Polarity Reversal/Mini Call Accounting 0=No
General:
This program assigns SMDR parameters.
Description:
01. Call duration start time:
This parameter assigns the start time for the Call duration timer.
0 = 00 seconds 1 = 05 seconds 2 = 10 seconds 3 = 15 seconds
4 = 20 seconds .............. 9 = 45 seconds
02. Record Incoming Calls:
This parameter decides whether incoming calls will be recorded.
0 = Record 1 = Do not Record
03. Record Local Calls:
The system decides which are local calls by the toll access code set in Mode 05-03-05.
04. Record Incoming Calls No Answer:
This parameter decides whether unanswered incoming calls will be recorded.
0 = Record 1 = Do not Record
05. Print out the Title:
This parameter decides whether the system will output the description of each column.
0 = Print out the Title. 1 = Do not print out the Title.