G1E Programming Manual
69
05. SLT Hookflash Answer Delay:
This parameter when enabled will prevent an SLT phone from activating a Hookflash until the time set
has expired.
0 = disable 1 = 1 sec. 2 = 2 sec. ……… 9 = 9 sec.
06. Speed Dialling Distribution:
This parameter sets the number of speed dial numbers allocated to the system speed dial. Adding extra
numbers to system Speed Dial reduces the number of personal Speed Dial numbers available to share
between individual stations.
0 = System 100 (100 to 199) : Individual 800/400 = DEFAULT
1 = System 200 (100 to 299) : Individual 700/300
2 = System 300 (100 to 399) : Individual 600/200
3 = System 400 (100 to 499) : Individual 500/100
4 = System 500 (100 to 599) : Individual 400/000
5 = System 600 (100 to 699) : Individual 300/000
6 = System 700 (100 to 799) : Individual 200/000
7 = System 800 (100 to 899) : Individual 100/000
8 = System 900 (100 to 999) : Individual 000/000
Numbers after backslash indicate sets available with name feature enabled. When names are
enabled (default) then the maximum number of system speed dials is 500.
07. Single Digit Intercom:
Single digit intercom allows the stations to call up to 5 other stations by dialling one digit only (1 to 5).
This feature is for the Hotel / Motel Environment. Up to eight different groups may be programmed. If a
group is not programmed with any entries then stations which are in the same number station group will
be able to make intercom calls without dialling the room to room dialling prefix (6). Single digit
destinations are programmed in Mode 10-gp
0 = Disable 1 = Enable
08. Message Waiting Method for Analogue Phones:
If the setting is 90VDC the analogue phone will receive a 90VDC signal when left a message. This is for
use with the industry standard MW telephones to turn on message lamp.
If the setting is Ring, the analogue phone will receive 30 seconds intercom ringing every 5 minutes until
the station answers.
If the setting is 250 ms. ring the analogue phone will receive two 250 ms. ring burst every 5 minutes.
This is for use with the special telephones to turn on the message lamp.
0 = 90V DC 1 = Ring 3 = Two 250 ms. Ring