EasyManua.ls Logo

HYBREX G1E - Program 05-14-Ip: System Timing Parameters - 14; Slt Lcr Switch on Delay for Pstn; Eserved; Reserved

Default Icon
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88 Issue 3.3.2 / April, 2011
Program 05-14-IP : System Timing Parameters – 14
05-14-IP SYS PAR
0 0 0 0 0 1 0 0
IP = 01-08
System Default.
Item Display Programming Data Timing
Pointer Data Description Table Default
---------- ---------- -------------------------------------------------- ---------- ------------
01 0-1 SLT LCR Switch on Delay for PSTN 0=Disable
02 0- Reserved 0 =
03 0- Reserved 0=
03 0- Reserved 0=
05 0- DISA DTMF Detect Delay Time 0=Disable
06 0-1 CID Delay Ring Time 1=1 Sec
07 0- Reserved 0=
08 0- Reserved 0=
Description:
01. SLT LCR Switch on Delay For PSTN.
This parameter delays the connection of SLT phones direct to PSTN lines when LCR is in use to prevent
the SLT dialling from conflicting with the LCR dialling.
0 = Disable 1 = 3 seconds delay. 4 = 6 seconds delay.
02. Reserved:
03. Reserved
04. Reserved
05. DISA DTMF Detect Delay Time:
This parameter will delay the system from detecting DTMF tones on a DISA call for a selected period of
time after DISA answers
0 = Disable 1 = 1 Second …… 9 = 9 seconds

Table of Contents