G1E Programming Manual
67
05. Toll Access Code:
The first digit that is checked for verification of a toll call. This has no effect on toll restriction within the
system. It is only used to notify SMDR that a particular call is a toll call. See Mode 14-01-03. With 8 digit
local numbering plans in use this parameter is not always useable.
0 = beginning with 0, 1 = 1, 2 = 2, ……..9 = 9
06. Station Numbering Plan:
This parameter assigns the number of digits used for the station numbering plan. 2, 3, or 4 digits may
be used. In the G1E the system will set this parameter to 3 digits automatically at the time of system
initialisation.
2 = 2 Digits 3 = 3 Digits 4 = 4 digits
07. Internal Dial Tone Pattern:
This parameter assigns the pattern of internal dial tone. If the parameter is set to 0 or 1 then analogue
phones will receive the special DND tone if call forward or DND has been set for that extension. Item 2
(and 6) is particularly designed for use when there is a Voice Mail system connected to the system as
some Voice mail units have problems with the broken dial tone. Item 6 will also provide what is known as
Stutter dial tone to extensions when they are left a message, useful where phones do not have a
message light. When this is enabled as well as MW direct to handsets by other methods the phones with
messages will receive both Message light and stutter dial tone.
Setting Intercom DND CFW MW
0 Steady SP. SP. Steady
1
Interrupted
SP. SP.
Interrupted
2 Steady Steady Steady Steady
3
Interrupted Interrupted Interrupted Interrupted
4 Steady SP. SP.
Interrupted
5
Interrupted
SP. SP. Steady
6 Steady Steady Steady
Interrupted
7
Interrupted Interrupted Interrupted
Steady
MW: Message Waiting. DND: Do not disturb. CFW: Call Forward.
08. Door Phone Ring Pattern:
This parameter allows for different ring patterns for the Door Phone. This Parameter will also affect the
ACP phone. If this mode is set to = 0 then the ACP will follow the extension ringing frequency otherwise
it will follow settings in this Mode.
0 = Continuous ring
1-8 = Ring using Ring frequency 1 to 8 of the DK handset.
9 = Background Music

Table of Contents