G1E Programming Manual
65
05. Exchange Line Flash Time - Key Phone & Analogue Phone:
This parameter permits the selection of Flash time for Key stations when pressing the [TRF/FL] key or
an analogue phone which presses flash and then dials 800 while connected to an outside line. After
dialling 800 the flash signal will be sent to the exchange line and the analogue phone will reconnect to
the exchange line.
See timing table Grade B for parameters of this feature.
06. SLT Hold Signal:
This parameter permits the selection of the Flash time from a single line telephone that the system will
see as a Hold signal if the time is greater than the hold signal but less than the SLT release time.
See timing table Grade I for parameters of this feature.
DURING
CONVERSATION
HOOK PRESSED-Period B
HOOK RELEASED
Period B < SLT Release Time
Hold
DURING
CONVERSATION
HOOK PRESSED-Period B
HOOK RELEASED
Period B > SLT Release Time
Hang Up
07. Ring On Time:
This parameter allows the system to identify Ring On Time Interval from the Exchange.
See timing table Grade G for parameters of this feature. This parameter should never be changed
without a clear understanding of the operation of the feature.
08. Ring Off Time:
This parameter allows the system to identify Ring Off Time Interval from the Exchange. This parameter
should never be changed without a clear understanding of the operation of the feature.
See timing table Grade F for parameters of this feature.
TIMING TABLE
Grade 0 1 2 3 4 5 6 7 8 9 Unit
B 40 80 160 240 400 600 800 1000 1200 1400 ms.
B(UK,
Italy,
Aust )
60 80 100 120 140 160 180 200 300 600 ms.
C 0 2 4 6 8 15 30 60 120 254 Sec.
F 2 2 2 3 4 5 6 7 8 9 Sec.
G 0 160 240 360 440 560 640 760 840 960 ms.
I 70 80 100 200 300 400 500 600 700 800 ms.