82 Issue 3.3.2 / April, 2011
Program 05-11-IP : System Timing Parameters – 11
05-11-IP SYS PAR
0 0 1 2 0 2 5 0
IP = 01-08
System Default.
Item Display Programming Data Timing
Pointer Data Description Table Default
---------- ---------- -------------------------------------------------- ---------- ------------
01 0-4 DTMF Caller ID Leading Digit 0=None
02 0-1 DISA Password – 1 / 50 Sets 0=1
03 0-2 Select Music on Hold or Ring Back Tone 1=MOH
04 0-1 DISA & ECF Access Delay Time - Night C 2=Wait
05 0-3 DISA Special Function Access 0=[8],[9],[*],[#]
06 0-9 DISA Re-check Times To Busy Console 2=4 Times
07 0-9 Door Phone Ringing Time 5=30 Sec.
08 0-8 DISA Single Digit Dialling 0=Disable
Description:
01. DTMF Caller ID leading Digit:
This parameter defines the start digit of DTMF caller ID signal. The system will omit the start digit for
CLI data on the display phone and CLI list.
02. Number of DISA Passwords:
This parameter when enabled will increase the number of DISA passwords from 1 to 50. At the default
setting of 0 the DISA password will be set in mode 13-02. If the parameter is set to 1, 50 passwords are
available and they will be the same as the forced account codes numbers (50-99). Forced account
codes are set in Mode 17-(01-99).
0 = 1 password 1 = 50 Passwords
03. Select Music on Hold or Ring Back Tone:
This parameter selects what the incoming caller will hear during Ring Transfer and Hold Recall
conditions. The feature is designed for Australia to prevent the caller incorrectly recognizing the
HYBREX's International Ring Back Tone as a disconnect or engaged signal and hanging up even
though their call is still in progress.
0 = Ring Back Tone 1 = Music On Hold 2 = Silence
04. DISA & ECF Access Delay time – Night:
This parameter sets the time duration that a DISA / ECF trunk will ring prior to connection with Voice
message during night switch. Stations can answer during this time interval.
0 = Automatic connection, no ring to the stations.
1-8 = Automatic connection after 2-254 seconds ringing.
See timing table grade C for parameters for this feature.