118 Issue 3.3.2 / April, 2011
Program 11-IP : Date and Time Setting
11-IP Date/Time
08 27 06 18 16 4
IP = 01-06
Setting Data
Item Display Programming Data
Pointer Data Description
----------- ----------- -----------------------------------------------
01 01-12 Month......................
02 01-31 Day........................
03 00-99 Year.......................
04 00-23 Hour.......................
05 00-59 Minute.....................
06 1-7 Week day (Monday = 1, Tuesday = 2)..
General:
This program permits the setting of system Date & Time.
Description:
The Date & Time will be held during a power failure on the G1E. There is no need to reset the Time after power
is restored.
Program 12-nn : System Alarm Clock
12-nn Alarm
hh mm dd
nn = Alarm schedule (01-10)
Setting Time
Location Display Programming Data
Pointer Data Description
----------- ---------- ---------------------------
hh 00-23 Hour.
mm 00-59 Minute.
dd 00-99 Duration.
General:
This program permits the assignment of 10 time schedules for alarm clock purposes.
Description:
When the assigned time is reached, Background music will be broadcast over all Key telephones, which are idle.
The time duration for alarm clock music is programmable (00 to 99 minutes.).