EasyManua.ls Logo

HYBREX G1E - Program 05-18-Ip: System Timing Parameters - 18; Led Maintenance; Reserved; Dial out History Feature

Default Icon
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96 Issue 3.3.2 / April, 2011
Program 05-18-IP : System Timing Parameters – 18
05-18-IP SYS PAR
0 0 0 0 0 0 8 5
IP = 01-08
System Default.
Item Display Programming Data Timing
Pointer Data Description Table Default
---------- ---------- ----------------------------------------------------------- ---------- ------------
01 0- Led Maintenance 0= Disable
02 0- Reserved 0=
03 0-1 Dial out History Feature 0=Disable
04 0- FSK Standard for Caller ID 0= Bellcore
05 0-9 Security alarm and fire alarm stop timer 0= No limit
06 0-1 Play Transfer message for ECF 0=
07 0-9 High Frequency Level of DTMF Generator
0=
08 0-9 Low Frequency Level of DTMF Generator
0=
Description:
01. LED Maintenance:
This parameter sets the LED maintenance feature. The LED Maintenance feature checks that the status
of LED’s is correct and no indications are lost.
0 = Disable 1 = Enable
02. Reserved:
03. Dial Out History Feature:
This parameter enables a dial out history memory buffer. When this feature is enabled the user can
press [Redial] and using the Up/down volume keys can scroll through the last 10 dialled out numbers
and then by pressing the [SPK] key dial any of the numbers.
Each phone has 2 blocks available, when this feature is enabled Block A will be used for CLI numbers
and Block B will be used for Dial out History.
0 = Disable 1 = Enable
04. FSK Standard For Caller ID:
This parameter selects between Bellcore/Etsi standard and Stentor Canadian Standard.
0 = Bellcore 1 = Stentor

Table of Contents