G1E Programming Manual
137
If door key has been set in mode 07 and mode 39 and the sensor of the door phone is in use, the Door key on
DSS will get the following indications:
LED Indication
Door Phone Status
Off Normal Close for Sensor
Red-Slow Flashing Normal Open for Sensor
Red-Fast Flashing Door Phone Is Calling
Green on This Station is talking to Door Phone
Red on Some other Station is talking to Door Phone
1.[PROG][7][SAVE][39][135][SAVE][REDIAL](Clear)[05][1](Normal open)[SAVE]
Where 135 is the number of the ACP in this example
Security feature
1.09-105=0294150100
2.17-01=1234dddd
3.36-01=01 02 03 04
4. 07-gp-xx assign FCN 61 to a soft key
5.67-01=55 0
6.68-01=111 112 113 114 OR Default ring is to Mode 03
7. ACP (135) press [PROG][5]See PASS or ERR to check sensor state [1234][#] To enable Security
feature
8. Or Keyphone presses [FN:61] the system will count down 1 minute then enable security feature.
9. ACP (135) presses [CALL] button
10. ST:111 , ST:112 ,ST:113 and ST:114 Ringing
11. System will get TK:01 (Mode 36 search idle trunk)and dial out 0294150100 then play “Message 227”
Someone is pressing your doorbell. please press [*] to talk to the visitor, and press [*] again to end the
conversation.
12. Outside party (TK:01) press [*] (before the 1 minute timeout) to talk with ACP(135) and all extensions
stop ringing.
13. Outside party presses [0] to open the door
. 14. Outside party (TK:01) presses [*] again will cut off the line
15. After user returns pressing [PROG][7][1234][#] on ACP (135) will disable the security feature
16. Or Keyphone presses [FN:61][1234][#] to disable the security feature.