2. Connect the 220 VAC power cable to the plasma power supply from the cooler.
At least one 120 VAC power cable is necessary for all cutting
systems. Some cutting systems use one 120 VAC power cable and
one 220 VAC power cable.
Refer to Power cables, 220 VAC on page 424 for lengths and part
numbers.
3. Connect the 120 VAC power cable to the plasma power supply from the gas connect console.
At least one 120 VAC power cable is necessary for all cutting
systems. Some cutting systems use one 120 VAC power cable and
one 220 VAC power cable.
Refer to Power cable, 120 VAC on page 424 for lengths and part
numbers.
4. Connect the CAN cable to the plasma power supply from the cooler.
Refer to CAN cables on page 425 for lengths and part numbers.
5. Connect the pilot-arc cable to the plasma power supply from the gas connect console.
Refer to Pilot-arc cables with strain relief on page 423 for lengths
and part numbers.
6. Connect both negative cables to the plasma power supply from the gas connect console.
Figure 23 - Negative cable with strain relief
Installation
3
109811530Instruction ManualXPR460