EasyManua.ls Logo

Hypertherm XPR460 - Page 110

Hypertherm XPR460
532 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 23 - Negative cable with strain relief (continued)
1 Outer nut
2 Strain relief nut
3 Inner nut
4 To plasma power supply
5 To gas connect console
* The sheet metal of the internal console panel intersects here.
Refer to Negative cables with strain relief on page 423 for lengths
and part numbers.
a. Remove the inner nut from the strain relief assembly on each negative cable.
b. Put the cable and strain relief nut for both negative cables through the holes in the sheet metal
panel.
c. Put the inner nut from the strain relief assembly over the end of each negative cable.
d. Tighten the inner nut to the strain relief nut for each negative cable.
7. Connect both work cables to the plasma power supply from the cutting table.
Figure 24 - Work cable with strain relief
1 This end goes to the plasma power supply.
2 This end goes to the cutting table.
At least one work cable is necessary for all cutting systems. Some
cutting systems use two work cables.
Refer to Work cables on page 431 for lengths and part numbers.
Installation
3
110
811530 Instruction Manual XPR460

Table of Contents

Related product manuals