b. Before you put the negative cables through the holes in the sheet metal panel on the gas
connect console, remove the two M3 hex nuts to remove the cover for the second strain-relief
mounting hole.
c. Put the cable and strain relief nut for both negative cables through the holes in the sheet metal
panel.
d. Put the inner nut from the strain relief assembly over the end of each negative cable.
e. Tighten the inner nut to the strain relief nut for each negative cable.
5. For ease of access, remove the top insulation panel by moving it horizontally before you connect the
pilot-arc cable.
6. Connect the pilot-arc cable to the gas connect console from the plasma power supply.
The strain relief nut on the pilot-arc cable is not necessary for this
connection. Remove the nut from the cable and tighten the strain
relief to the panel on the gas connect console.
Figure 30 - Connections complete for the gas connect console
1
1
2
3
4
4
5
5
Installation
3
117811530Instruction ManualXPR460