a. Connect the coolant-return hose with the red bands to the coolant-return fitting with the red
band.
b. Connect the coolant-supply hose with the green bands to the coolant-supply fitting with the
green band.
2. Connect the female cable connector on the 120 VAC power cable to the gas connect console from
the plasma power supply.
At least one 120 VAC power cable is necessary for all cutting
systems. Some cutting systems use one 120 VAC power cable and
one 220 VAC power cable.
3. Connect the female cable connector on the CAN cable to the gas connect console from the cooler.
4. Connect the negative cable or cables to the coolant manifold in the gas connect console from the
plasma power supply.
Figure 29 - Negative cable with strain relief
1 Outer nut
2 Strain relief nut
3 Inner nut
4 To plasma power supply
5 To gas connect console
* The sheet metal of the internal console panel intersects here.
At least one negative cable is necessary for all cutting systems. Some
cutting systems use two negative cables.
a. Remove the inner nut from the strain relief assembly on each negative cable.
Installation
3
116
811530 Instruction Manual XPR460