Refer to Connect the gas connect console (VWI, OptiMix) to the TorchConnect console on page
123.
The number and type of gas hose connections is based on the type of gas connect console you have.
Pilot-arc, coolant-hose, and shield-water assembly
Power, CAN, and 5-gas assembly
Connect the torch-lead assembly to the torch receptacle.
Refer to Install the torch-lead assembly to the torch receptacle on page 136.
Connect the torch-lead assembly to the TorchConnect.
Refer to Connect the torch lead to the TorchConnect console on page 141.
Make sure that the hoses, cables, and leads are correctly installed.
Correct type and correct installation
No damage or kinks
No coils in cables that can create EMI problems
Distances between high-frequency leads and control cables obey requirements
Distances for communications obey requirements
Remove the torch and consumable parts.
Refer to Remove the torch and consumable parts on page 143.
Install the torch into the torch receptacle.
Refer to Install the torch into the torch receptacle on page 145.
Install the torch mounting bracket.
Install the torch mounting bracket onto the torch lifter.
As an installer or user, you must supply the motorized torch lifter for your cutting system. Refer to
Torch lifter requirements on page 70.
Install the torch in the torch mounting bracket on page 147.
As an installer or user, you must supply the torch mounting bracket for your cutting system. Refer
to Torch mounting bracket requirements on page 70.
Install the consumables.
Refer to Install the consumables on page 149.
Make sure the consumables are the correct type and correctly installed.