Table 1. Start Table (continued)
Symptom What You Should Do
There is an IPL problem (the system
attention light is off and no SRC in function
5).
Go to Analyzing IPL Problems on page 22.
There is a Device Not Found message
during an install from an alternate
installation device.
Go to TU-PIP6 on page 459.
System operations have stopped or the
system is in a loop (the system attention
light is off).
Go to System Hangs or Loops (No SRC)
on page 31.
On a system that has multiple logical partitions, there is a problem with a secondary
partition and the symptom is:
There is a B2xx xxxx SRC on the Work with
Partition Status screen of the Primary
console.
Go to Chapter 2. Unit Reference Codes on
page 59.
One or more of the following was reported:
v The console of a secondary partition was
lost or is not functioning.
v There is an SRC on the panel of an I/O
expansion tower owned by a secondary
partition.
v You suspect a power problem with
resources owned by a secondary partition.
v There is an IPL problem with a secondary
partition and there is an SRC on the Work
with Partition Status screen of the Primary
or secondary partition.
v The secondary partition’s operations have
stopped or the partition is in a loop and
there is an SRC on the Work with Partition
Status screen of the Primary or secondary
console.
v Search the Primary partitions Service
Action Log. Go to Using the Service
Action Log on page 9.
v If you dont find an entry in the Service
Action Log of the Primary partition then
record the partitions SRC from the Work
with Partition Status screen of the Primary
partitions console. See iSeries Service
Functions. Use that SRC and go to
Chapter 2. Unit Reference Codes on
page 59.
Perform service from the secondary
partition unless instructed to move to
another partition.
The partitions console is functioning and in
the Work with partition status screeninthe
Primary partition or secondary partition, the
state of the partition is Failed or Unit
Attn. and there is a system reference code.
See iSeries Service Functions.
Use the partitions SRC. From the partitions
console search for that SRC in the partitions
Service Action Log. Go to Using the Service
Action Log on page 9.
One or more of the following was reported:
v There is an IPL problem with the
secondary partition and there is no SRC
displayed in the Work with Partition Status
screen.
v The partitions operations have stopped or
the partition is in a loop and there is no
SRC displayed in the Work with Partition
Status screen.
v Go to Logical Partition Hangs or Loops
(No SRC) on page 34.
Starting Point
Chapter 1. Starting Problem Analysis 7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals