5-16
SECTION 5
COMMON PRACTICES
5-1-8 ENCODING 2-TONE SEQUENTIAL FORMAT
This procedure configures the RF Generate Operation Screen to encode using the
2-Tone Sequential format.
This example assumes an FM pager requires a first tone of 650 Hz for
500 ms and a second tone of 850 Hz for 1.5 sec. with a 0.25 sec. gap.
P
R
E
P
o Set RF Field to
Pager Center Frequency
.
o Set Output Level to
-30 dBm
.
o Set Output to
T/R
.
o Select
GEN1
for Modulation Source.
o Set Modulation Type to
FM
.
o Set Deviation to
5.0 kHz
.
o Set Format to
USER
.
o Cursor to Format Field and press F4
CONFIG
.
o Edit the USER SIGNALING PROGRAM pop-up window to read:
USER SIGNALING PROGRAM
CHAR
FREQ (Hz) DUR (ms)
0 0.0 250
1 650.0 500
2 850.0 1500
o Press F6
RETURN
.
o Cursor to Code Field and press F1
CLEAR
.
o Attach an antenna to the T/R Connector.
o Enter
102
.
o Cursor to Format Field and Press F3
BURST
or F2
CONT
to set off the pager.