DC FUSE REPLACEMENT
ο Disconnect all external power connections.
ο Use a slotted tool to depress DC FUSE Holder (1) and turn counter clockwise.
ο Remove DC FUSE Holder and remove fuse.
Insure proper fuse is installed in DC FUSE Holder.
Fuse provided:
10 A, 32 V, Type F, AGC fuse for dc operation.
ο Replace fuse and reinstall DC FUSE Holder.
BATTERY REPLACEMENT
The following procedure should be followed when replacing the battery.
WARNING:
THE BATTERY USED IS A SEALED LEAD-ACID BATTERY
PACK. THE FOLLOWING WARNINGS CONCERNING LEAD-ACID
BATTERIES MUST BE HEEDED.
DO NOT CRUSH, INCINERATE OR DISPOSE OF IN NORMAL
WASTE. PROPER DISPOSAL FOR DISCARD OF BATTERY IS
REQUIRED. REFER TO APPROPRIATE STATE AND LOCAL
REGULATIONS FOR INSTRUCTIONS AS TO PROPER
DISPOSITION OF DISCARDED BATTERIES.
DO NOT RECHARGE OUTSIDE THE COM-120C.
DO NOT SHORT CIRCUIT OR FORCE DISCHARGE AS THIS MIGHT
CAUSE THE BATTERY TO VENT, OVERHEAT OR EXPLODE.