6-39
SECTION 6
OPTIONS
o If Distortion/DTMF Meter Operation is required, select desired Meter.
o Configure Deviation Meter (16).
o Select Input (20) for desired Input Connector. Selections include T/R (T/R
Connector) and ANT (ANTENNA Connector).
If Mobile Radio output is >0 dBm, select T/R. If ANT Input (20) is selected and
Mobile Radio Output is >30 dBm, set Attenuation (21) for 30 dB.
o Set Attenuation (21). Selections include 0 dB and 30 dB. If ANT Input (20) is
selected and Mobile Radio Output is >30 dBm, set Attenuation (21) for 30 dB.