6-111
SECTION 6
OPTIONS
8. Rx SINAD
Minimum permissable receiver SINAD, in dB. Since the COM-120C GEN1 is used
to generate the test signal, direct audio connections are required to perform this
measurement.
9. Rx Distortion
Maximum permissable receiver distortion, as a percentage. Since the COM-120C
GEN1 is used to generate the test signal, direct audio connections are required to
perform this measurement.
10. Rx AF Level
Minimum and maximum permissable receiver audio level, in Vrms. Since the
COM-120C GEN1 is used to generate the test signal, direct audio connections are
required to perform this measurement.