3.1.7. Unused Transceiver Channel
To preserve the performance of unused transceiver channels, Intel Quartus Prime
software can switch the TX/RX channels on and off at a low frequency using an
reference clock. To create clock activity on unused channels by way of a Intel Quartus
Prime Settings File (.qsf) variable, either:
Make a global assignment: set_global_assignment -name
PRESERVE_UNUSED_XCVR_CHANNEL ON
Use a per-pin assignment: set_instance_assignment -name
PRESERVE_UNUSED_XCVR_CHANNEL ON -to pin_name
For example, if the pin_name is Pin AB44, structure the per-pin assignment with the
following syntax: set_instance_assignment -name
PRESERVE_UNUSED_XCVR_CHANNEL ON -to AB44.
3.2. Physical Coding Sublayer (PCS) Architecture
The Intel Stratix 10 E-Tile PCS is located in the EHIP_LANE block, which includes the
following features:
64B/66B encoder/decoder
Scrambler/descrambler
Block distribution/block synchronization
Lane reorder
The PCS features are not available within the Native PHY IP core. Refer to the Intel
Stratix 10 E-Tile Hard IP for Ethernet IP Core User Guide for details about the
EHIP_LANE block.
Related Information
E-Tile Hard IP for Ethernet Intel FPGA IP User Guide
3.3. Reed Solomon Forward Error Correction (RS-FEC) Architecture
The Intel Stratix 10 E-Tile includes a Reed Solomon Forward Error Correction (RS-FEC)
block.
For more basic RS-FEC information, refer to AN 846: Intel Stratix 10 Forward Error
Correction.
The RS-FEC core supports the following standards:
100GbE: IEEE 802.3 Clause 91
100GbE with KP-FEC: IEEE 802.3 Clause 91
128GFC: Fibre Channel Framing and Signaling - 4 (FC-FCS-4) Clause 5.6
25GbE: IEEE 802.3 Clause 108
32GFC: Fibre Channel Framing and Signaling - 4 (FC-FCS-4) Clause 5.4
3. Intel Stratix 10 E-Tile Transceiver PHY Architecture
UG-20056 | 2019.02.04
Send Feedback
Intel
®
Stratix
®
10 E-Tile Transceiver PHY User Guide
79

Table of Contents

Other manuals for Intel Stratix 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel Stratix 10 and is the answer not in the manual?

Intel Stratix 10 Specifications

General IconGeneral
BrandIntel
ModelStratix 10
CategoryControl Unit
LanguageEnglish

Related product manuals