The switch supports these alarms:
•
Chassis alarms indicate a failure on the switch or one of its components. Chassis alarms
are preset and cannot be modified.
•
System alarms indicate a missing rescue configuration. System alarms are preset and
cannot be modified, although you can configure them to appear automatically in the
J-Web interface display or the CLI display.
Alarm Severity Levels
Alarms on switches have two severity levels:
•
Major (red)—Indicates a critical situation on the switch that has resulted from one of
the following conditions. A red alarm condition requires immediate action.
•
One or more hardware components have failed.
•
One or more hardware components have exceeded temperature thresholds.
•
An alarm condition configured on an interface has triggered a critical warning.
•
Minor (yellow or amber)—Indicates a noncritical condition on the switch that, if left
unchecked, might cause an interruption in service or degradation in performance. A
yellow alarm condition requires monitoring or maintenance.
A missing rescue configuration generates a yellow system alarm.
Related
Documentation
Checking Active Alarms with the J-Web Interface on page 246•
• Dashboard for EX Series Switches on page 49
Checking Active Alarms with the J-Web Interface
Purpose NOTE: This topic applies only to the J-Web Application package.
Use the monitoring functionality to view alarm information for the EX Series switches
including alarm type, alarm severity, and a brief description for each active alarm on the
switching platform.
Action To view the active alarms:
1. Select Monitor > Events and Alarms > View Alarms in the J-Web interface.
2. Select an alarm filter based on alarm type, severity, description, and date range.
3. Click Go.
All the alarms matching the filter are displayed.
Copyright © 2015, Juniper Networks, Inc.246
EX4550 Switch Hardware Guide

Table of Contents

Other manuals for Juniper EX4550

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4550 and is the answer not in the manual?

Juniper EX4550 Specifications

Console Connection Settings IconConsole Connection Settings
baud rate9600
data bits8
stop bits1

Related product manuals