Loading...
switch temperature monitor shutting down the switch to protect the hardware
components.
Table 40 on page 73 provides the required environmental conditions for normal switch
operation.
Table 40: EX Series Switch Environmental Tolerances
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C) at
altitudes up to 5,000 ft
(1,524 m).
For information about extended
temperature SFPs, see Pluggable
Transceivers Supported on
EX2200 Switches.
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet
(1524 meters)
EX2200-C
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX2200
(except
EX2200-C
switches)
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX3200
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX3300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX4200
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX4300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)