14. Power on the services gateway. The OK LED on the power supply faceplate should blink, then light
steadily.
15. Verify that the MPC is functioning correctly by issuing the show chassis fpc and show chassis fpc
pic-status commands. For example:
user@host> show chassis fpc
node0:
--------------------------------------------------------------------------
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 23 0 2048 19 14
1 Offline ---Offlined by cli command---
2 Online 49 37 0 1024 14 25
Bring the MPC online for the first time by using the following CLI command:
user@host> request chassis fpc slot 1 online
node0:
--------------------------------------------------------------------------
Online initiated, use "show chassis fpc" to verify
user@host> show chassis fpc
node0:
--------------------------------------------------------------------------
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 6 0 2048 19 14
1 Online 44 11 0 1024 23 29
2 Online 49 22 0 1024 14 25
user@host> show chassis fpc pic-status
Slot 0 Online SRX5k SPC II
PIC 0 Online SPU Cp
PIC 1 Online SPU Flow
PIC 2 Online SPU Flow
PIC 3 Online SPU Flow
Slot 1 Online SRX5k IOC II