Loading...
Firmware package is available on the USB flash drive and the firmware version matches the version of
Junos OS currently installed on the device. Use the show version command to identify the Junos OS
version. You can download the firmware from https://support.juniper.net/support/downloads/
The chassis cluster has only two redundancy groups (RG0 and RG1) configured.
This procedure includes the steps for replacing the Routing Engine on node 0 of a chassis cluster setup.
You can follow the same steps to replace the Routing Engine on node 1.
To replace a Routing Engine on node 0 of a chassis cluster using a USB flash drive:
1. Prepare to shut down node 0:
a. Perform a manual failover of the redundancy groups (RGs) from node 0 to node 1.
Fail over RG1:
root@node0> request chassis cluster failover redundancy-group 1 node 1
Fail over RG0:
root@node0> request chassis cluster failover redundancy-group 0 node 1
b. Verify that both RGs are active on node 1 after the failover:
root@node0> show chassis cluster status
{secondary:node0}
root@node0> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring
Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures
Redundancy group: 0 , Failover count: 1
node0 129 secondary no no None
node1 255 primary no no None
Redundancy group: 1 , Failover count: 1
node0 129 secondary no no None
node1 255 primary no no None