{primary:node1}
root@node1> show chassis cluster interfaces
Control link status: Down
Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Down Disabled Disabled
1 em1 Down Disabled Disabled
Fabric link status: Down
Control interfaces:
Name Child-Interface Status Security
(Physical/Monitored)
fab0 xe-11/0/3 Down / Down Disable
fab0
g. Power on node 0.
5. Load the configuration file and scripts on the new Routing Engine:
a. Log in to the Routing Engine on node 0 from the console.
b. Configure the root password and the IP address for the fxp0 interface. Do not commit the
configuration.
NOTE: You need not configure a gateway as the assumption is that the fxp0
interfaces on both nodes are in the same subnet.
root@node0> edit
root@node0# set system root-authentication plain-text-password
New password: type password here
Retype new password: retype password here
root@node0# set interfaces fxp0 unit 0 family inet address IP-address
The chassis cluster information is stored in the Switch Control Board (SCB). The device comes up
with the cluster enabled and does not allow a commit without the cluster port configuration. Apply
the node 1 port configuration on node 0.
You can view the control port configuration from node 1: