Table 53: Chassis Component Alarm Conditions on SRX5400, SRX5600, and SRX5800 Services
Gateways (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
Yellow
•
Check room
temperature.
•
Check air filter and
replace it.
•
Check airflow.
•
Check fan.
The chassis temperature
has exceeded 55 degrees C
(131 degrees F), the fans
have been turned on to full
speed, and one or more
fans have failed.
Temperature
Yellow
•
Check room
temperature.
•
Check air filter and
replace it.
•
Check airflow.
•
Check fan.
The chassis temperature
has exceeded 65 degrees C
(149 degrees F), and the
fans have been turned on
to full speed.
Red
•
Check room
temperature.
•
Check air filter and
replace it.
•
Check airflow.
•
Check fan.
The chassis temperature
has exceeded 65 degrees C
(149 degrees F), and a fan
has failed. If this condition
persists for more than 4
minutes, the Services
Gateway shuts down.
Red
•
Check room
temperature.
•
Check air filter and
replace it.
•
Check airflow.
•
Check fan.
Chassis temperature has
exceeded 75 degrees C
(167 degrees F). If this
condition persists for more
than 4 minutes, the Services
Gateway shuts down.
RedThe temperature sensor has
failed.
352