Section 7: SCPI command reference Series 2280 Precision DC Power Supply Reference Manual
7-112 077085503 / March 2019
:SYSTem:BEEPer:ERRor[:STATe]
This command allows you to turn the beeper on or off.
Type
Affected by
Where saved
Default value
Command and query
Recall settings
Instrument reset
Power cycle
Save settings
1 (ON)
Usage
:SYSTem:BEEPer:ERRor[:STATe] <state>
:SYSTem:BEEPer:ERRor[:STATe]?
<state>
Disable the beeper: OFF or 0
Enable the beeper: ON or 1
Details
This command enables or disables the beeper for error messages. When enabled, a beep signals
that an error has happened.
Example
:SYSTem:BEEPer:ERRor ON
Enable the error beeper.
Also see
:SYSTem:KCLick (on page 7-119)