EasyManuals Logo
Home>Keithley>Power Supply>2280 Series

Keithley 2280 Series Reference Manual

Keithley 2280 Series
457 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #327 background imageLoading...
Page #327 background image
Section 7: SCPI command reference Series 2280 Precision DC Power Supply Reference Manual
7-126 077085503 / March 2019
:SYSTem:TIME
This command sets the absolute time of the instrument.
Type
Affected by
Where saved
Default value
Command and query
Not applicable
Nonvolatile memory
See Details
Usage
:SYSTem:TIME <hour>, <minute>, <second>
:SYSTem:TIME?
<hour>
Hour in 24-hour time format: 0 to 23
<minute>
Minute: 0 to 60
<second>
Second: 0 to 60
Details
The query command returns the present timestamp in the format:
<hour>,<minute>,<second>
Example
:SYST:TIME 5, 51, 30
Set the system time to 05:51:30.
Also see
:SYSTem:DATE (on page 7-115)
:SYSTem:VERSion?
This command queries the present SCPI standard version.
Type
Affected by
Where saved
Default value
Query only
Not applicable
Not applicable
Not applicable
Usage
:SYSTem:VERSion?
Details
This query command returns the SCPI standard version.
Example
:SYST:VERS?
Query the version. Example output:
1999.0
Also see
None

Table of Contents

Other manuals for Keithley 2280 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2280 Series and is the answer not in the manual?

Keithley 2280 Series Specifications

General IconGeneral
BrandKeithley
Model2280 Series
CategoryPower Supply
LanguageEnglish

Related product manuals