Section 7: SCPI command reference Series 2280 Precision DC Power Supply Reference Manual
7-126 077085503 / March 2019
:SYSTem:TIME
This command sets the absolute time of the instrument.
Type
Affected by
Where saved
Default value
Command and query
Not applicable
Nonvolatile memory
See Details
Usage
:SYSTem:TIME <hour>, <minute>, <second>
:SYSTem:TIME?
<hour>
Hour in 24-hour time format: 0 to 23
<minute>
Minute: 0 to 60
<second>
Second: 0 to 60
Details
The query command returns the present timestamp in the format:
<hour>,<minute>,<second>
Example
:SYST:TIME 5, 51, 30
Set the system time to 05:51:30.
Also see
:SYSTem:DATE (on page 7-115)
:SYSTem:VERSion?
This command queries the present SCPI standard version.
Type
Affected by
Where saved
Default value
Query only
Not applicable
Not applicable
Not applicable
Usage
:SYSTem:VERSion?
Details
This query command returns the SCPI standard version.
Example
:SYST:VERS?
Query the version. Example output:
1999.0
Also see
None