130 Keysight InfiniiVision HD3-Series Oscilloscopes User's Guide
9 Display Settings
To reset the label library to the factory default
1 From the menu, choose Setup > Display....
2 In the Display dialog box, select the Labels tab.
3 Select Reset Library.
This will delete all user-defined labels from the library and set the labels in the
library back to the factory default. However, this does not default the labels
currently assigned to the waveforms (those labels that appear in the waveform
area).
To add an annotation
You can add annotations to the oscilloscope's display. Annotations are useful for
documentation purposes, to add notes before capturing screens.
To add an annotation:
1 From the menu, choose Setup > Display....
2 In the Display dialog box, select the Annotations tab.
3 In the Annotations tab, in the Select Annotation list, select the desired
annotation.
You can define up to 20 annotations.
4 Select the Text field.
Selecting Reset Library will remove all user-defined labels from the library and set the labels
back to the factory default. Once deleted, these user-defined labels cannot be recovered.
Defaulting labels without erasing the default library
Pressing [Default Setup] sets all waveform labels back to the default labels but does not
erase the list of user-defined labels in the library.