EasyManua.ls Logo

Keysight InfiniiVision HD3 Series - 19 Frequency Response Analysis; To Make Connections

Keysight InfiniiVision HD3 Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
245
Keysight InfiniiVision HD3-Series Oscilloscopes
User's Guide
19 Frequency Response Analysis
To make connections / 245
To set up and run the analysis / 246
To view and save the analysis results / 247
The Frequency Response Analysis (FRA) feature controls the built-in waveform
generator to sweep a sine wave across a range of frequencies while measuring the
input to and output from a device under test (DUT). At each frequency, gain (A)
and phase are measured and plotted on a frequency response Bode chart.
When the frequency response analysis completes, you can move a marker across
the chart to see the measured gain and phase values at each frequency point. You
can also adjust the chart's scale and offset settings for the gain and phase plots.
To make connections
The waveform generator output is connected to a device under test (DUT). The
input to the device and the output from the device are probed by the oscilloscope's
input channels.

Table of Contents

Related product manuals